The panel failed a gauss test
A contract electronics manufacturer in Suzhou builds instrument housings, and one of the last operations before packing is a residual magnetism check, because a panel with a magnetic field on it will pull swarf into a connector bay and destroy a board the first time the unit is powered up.
Their limit was two gauss at the surface and one shipment of housings came in at five, and their quality manager sent me a photograph of a gauss meter held against a panel with the reading visible and no message at all, which is how that conversation usually starts.
The screws in that panel were 304 stainless steel machine screws, M3 by 6, and I want to say clearly that they were 304, because the first three emails of that week were spent proving it.
304 is magnetic after heading
The austenitic structure of 304 is non magnetic in the annealed state, and a sheet of it will not hold a magnet, and almost everybody in purchasing knows that and stops there.
A screw is not a sheet. It is cold headed from wire with a punch, and the head is formed in one or two blows at room temperature, and the deformation is severe, and the austenite partially transforms into strain induced martensite, which is magnetic.
The thread rolling adds more, because the thread is formed by squeezing rather than cutting, and the result is a screw that is genuinely 304 in chemistry and genuinely magnetic at the head and on the flanks, and a spectro will confirm the first and a gauss meter will confirm the second.
What the customer actually needed
He needed a screw with a residual field below his limit, and there are three ways to get one and only one of them was on his drawing.
The first is a different alloy, because 316 and its low carbon version work harden less sharply and end up with a weaker field, and that is a partial answer and it costs about a third more.
The second is annealing after heading, which restores the austenite and removes most of the magnetism and also takes the strength back down to the soft condition, which nobody wants in a screw.
The third is demagnetising, which does not change the structure at all and simply leaves the domains in a random orientation, and it is done by passing the parts through a coil with a decaying alternating field, and it takes about a second for a batch.
The demagnetising coil
The factory that made those screws did not have a coil, and the factory next door did, because it supplies the automotive sensor trade and every part it makes goes through one.
So the four hundred thousand screws went next door in two trips on a pallet, came back through a coil in an afternoon, and were packed with a note, and the field on a sample of twenty was under half a gauss at the head.
Two trips on a pallet. One afternoon of work. That is the difference between a shipment that passes a gauss test and one that comes back on a truck.
That is the whole fix. No change of material, no change of drawing, no scrap, and one afternoon of a subcontract operation that costs less than a fen a piece at that quantity.
What it costs per screw
The coil operation came to about three hundred yuan for the batch, which is under a fen a piece, and I did not charge for it because the specification had been mine to write and I had written 304 and stopped.
The rework at the customer's end was more expensive than the coil by a factor of about twenty, because a panel that has been assembled and tested and found magnetic has to be stripped and the boards put back in a different housing, and the housings are the cheap part and the labour is not.
I did not know any of this when I quoted. I learned it in the week after, from a quality manager who was patient with me and from a man at the plating shop next door who explained what a decaying alternating field does to a screw in about ninety seconds.
The specification I write now
Any 304 stainless steel machine screw going to an electronics customer now carries a line asking whether there is a magnetism limit, and if there is I quote the demagnetised version and put the gauss figure in the line rather than the process name.
I ask it because the question is not obvious and because a magnetic screw is invisible until somebody measures it, and because the customers who need it are exactly the ones who will never mention it in an enquiry, since to them it is a fact about their own process and not a fact about my product.
The factory direct price for 304 screws is real and it is the same price whether the parts are demagnetised or not, and the only difference between a batch that passes a gauss test and one that fails is an afternoon next door that nobody thinks to ask for.
Hot Tags: 304 stainless machine screws, electronics screws, demagnetised screws, residual magnetism, gauss test, 304 cold heading magnetism